Back to top

Conrad HF

Non-CE certified 32-50kW radiographic generator
The Conrad HF Series of high frequency radiographic generators delivers the highest performance and reliability in any medical radiographic environment.


Available from 30 - 50 kW power output, the ConRad HF Series of high frequency radiographic generators continue Control-X Medical’s tradition of providing Hospital Grade Quality products at exceptional prices.

  • Microprocessor control delivers reliability and accurate exposure parameter management.ConRad_console_1
  • Outstanding linearity, low ripple, 400, 500 or 600 mA maximum tube current.
  • “Easy-To- Use” fl at surface control panel.
  • Operates as a 3-factor technique selection generator (kVp, mA, time) with mAs operation selectable by operator.
  • Wide range of selectable exposure times for easy parameter selection and fl exibility.
  • Rapid automatic calibration mode reduces onsite procedure time.
  • Decreased x-ray dose as compared to traditional generator systems which ensures more patient safety.
  • Faster procedures due to improved x-ray techniques means more throughput.
  • Automatic tube protection and interlocks are all standard features.
  • Stored energy version available.

 

 

Options:

  • AEC electronics for consistent image quality.CONRAD APR console
  • 24 anatomical programs across 12 bodily regions.
  • Control console pedestal for easy accommodation.

 

 

 

 

 

 

 

 

Conrad HF Choice of Generators

 

 

Conrad drawings

 

Highlights

30 to 50 kW High Frequency Generator

The ConRad generator comes in to versions: the simple non-APR and the preprogrammed {APR|Anatomically Programmed Radiography: the optimal X-ray parameters are stored and used for each exposure technique / protocol. The parameter values can be customized and reprogrammed to meet specific requirements.} console variations. Three-phase or 16A single phase line configurations are available, with line matching transformers where necessary. Options include Bucky and {AEC|Automatic Exposure Control: ensures consistent image brightness under a wide range of exposure conditions} interfaces and high-speed tube rotation. Please note that the ConRad generators are FDA approved equipment, but have no CE certification.

Specifications

Generator

ConRad High Frequency Generator (30 – 50 kW)

  • Standard configuration: 30 kW, 25-400 mA and 40-125 kV range
  • Optional 150 kV max output
  • Microprocessor control, accurate exposure parameter management
  • Outstanding linearity, low ripple
  • Easy-to-use flat surface control panel
  • Operates as a 3-factor (kVp, mA, sec) or 2-factor (kV, mAs) generator, selectable by operator. KVp can be varied in 1 kVp steps from 40-125 kVp
  • Rapid automatic calibration mode reduces the onsite procedure time
  • Consistent image quality using the optional {AEC|Automatic Exposure Control: ensures consistent image brightness under a wide range of exposure conditions}
  • Automatic tube protection and interlocks are all standard features